Our organization has been focusing on brand strategy. Customers' gratification is our greatest advertising. We also source OEM provider for Patient Monitoring System , HT8 Modular Patient Monitor , Competitive Price Patient Monitor , Wanting on the long run, a protracted way to go, continually striving to become the all team with full enthusiasm, one hundred times the confidence and put our company created a beautiful environment, advanced merchandise, good quality first-class modern business and get the job done hard!
China Wholesale CMS Multi Parameter Patient Monitor Factories – H8 Multi Parameter Patient Monitor – Hwatime Detail:

Quick Details

H8 Multi Parameter Patient Monitor (1)

ECG Lead mode: 3-lead or 5-lead

ECG Waveform: 4-lead, dual-channel 3-lead, single-channel

NIBP Mode: Manual, Auto, STAT

NIBP Measurement and alarm range: 0 ~ 100%

NIBP Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified

PR Measurement and alarm range: 30 ~ 250bpm

PR Measurement accuracy: ±2bpm or ±2%, whichever is greater

Application: Bedside/ICU/OR, Hospital/Clinic

Supply Ability: 100 Unit/Per Day

Packaging & Delivery:

Packaging Details

One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.

Product packaging size (length, width, height): 410MM*280MM*360MM

GW: 5.5KG

Delivery Port: Shenzhen, Guangdong

Lead Time:

Quantity(Units)

1 - 50

51 - 100

>100

Est. Time(days)

15

20

To be negotiated

Usage

Portable Patient Monitor can be used to monitor multiple physiological parameters including ECG(3-lead or 5-lead), Respiration(RESP), Temperature(TEMP), Pulse Oxygen Saturation(SPO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure(IBP) and carbon dioxide(CO2). All the parameters can be applied for adult, pediatric and neonate patients. The monitoring information can be displaying, reviewing, storing and recording.

Product Description

Product name H8 Multi Parameter Patient Monitor
ECG Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Method Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5KΩ
Bandwidth: 0.3 ~ 2.5 Hz
NIBP Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN4.SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR Measurement and alarm range: 30 ~ 250bpm
Measurement accuracy: ±2bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50℃
Resolution: 0.1 ℃
Label:ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART : 0 ~ 300mmHg
PA: -6 ~ 120mmHg
CVP/RAP/LAP/ICP : -10 ~ 40mmHg
P1/P2: -10 ~ 300mmHg
Press Sensor Sensitivity: 5uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1mmHg
Accuracy: +-2% or +- 1mmHg, which great
Actualization interval: about 1 Sec. 7.EtCO2
Method: Side-stream or Mainstream
Measuring Range: 0~150mmHg
Resolution:
0~69mmHg, 0mmHg
70~150mmHg, 0.2mmHg
Accuracy:
0~40 mm Hg ±2mm Hg
41~70 mm Hg ±5%
71~100 mm Hg ±8%
101~150 mm Hg ±10%
Aw-RR Range: 2~150 rpm
Aw-RR Accuracy: ±1BPM
Apnoea Alarm: Yes
RESPARATION Respiratory monitoring principle
Respiration is measured by the thoracic impedance. When the patient is breathing, the volume of air changes in the lungs, resulting in impedance changes between the electrodes. Respiration rate (RR) is calculated from these impedance changes, and a respiration waveform appears on the patient monitor screen.
Method Impedance between R-F(RA-LL)
Differential Input Impedance:  >2.5MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5KΩ
Bandwidth: 0.3 ~ 2.5 Hz

Product detail pictures:

China Wholesale CMS Multi Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

China Wholesale CMS Multi Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

China Wholesale CMS Multi Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

China Wholesale CMS Multi Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

China Wholesale CMS Multi Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures


Related Product Guide:

It adheres to the tenet "Honest, industrious, enterprising, innovative" to develop new products constantly. It regards customers, success as its own success. Let us develop prosperous future hand in hand for China Wholesale CMS Multi Parameter Patient Monitor Factories – H8 Multi Parameter Patient Monitor – Hwatime, The product will supply to all over the world, such as: Egypt , Niger , UK , With the growing of the company, now our products sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 StarsBy Harriet from Brunei - 2018.09.16 11:31
    This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 StarsBy Hellyngton Sato from Chile - 2017.06.19 13:51

    Related Products