Quick Details

ECG Lead mode: 3-lead or 5-lead
ECG Waveform: 4-lead, dual-channel 3-lead, single-channel
NIBP Mode: Manual, Auto, STAT
NIBP Measurement and alarm range: 0 ~ 100%
NIBP Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified
PR Measurement and alarm range: 30 ~ 250bpm
PR Measurement accuracy: ±2bpm or ±2%, whichever is greater
Application: Bedside/ICU/OR, Hospital/Clinic
Supply Ability: 100 Unit/Per Day
Packaging & Delivery:
Packaging Details
One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.
Product packaging size (length, width, height): 410MM*280MM*360MM
GW: 5.5KG
Delivery Port: Shenzhen, Guangdong
Lead Time:
|
Quantity(Units) |
1 - 50 |
51 - 100 |
>100 |
|
Est. Time(days) |
15 |
20 |
To be negotiated |
Usage
Portable Patient Monitor can be used to monitor multiple physiological parameters including ECG(3-lead or 5-lead), Respiration(RESP), Temperature(TEMP), Pulse Oxygen Saturation(SPO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure(IBP) and carbon dioxide(CO2). All the parameters can be applied for adult, pediatric and neonate patients. The monitoring information can be displaying, reviewing, storing and recording.
Product Description
| Product name | H8 Multi Parameter Patient Monitor |
| ECG | Lead mode: 3-lead or 5-lead |
| Lead selection: I, II, III, aVR, aVL, aVF, V | |
| Waveform: 5-lead, dual-channel | |
| 3-lead, single-channel | |
| Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV | |
| Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Method Impedance between R-F(RA-LL) | |
| Differential Input Impedance: >2.5MΩ | |
| Measuring Impedance Range:0.3~5.0Ω | |
| Base line Impedance Range:0 – 2.5KΩ | |
| Bandwidth: 0.3 ~ 2.5 Hz | |
| NIBP | Method Oscillometric |
| Mode Manual, Auto, STAT | |
| Measuring Interval in AUTO Mode | |
| 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) | |
| Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm | |
| Alarm Type: SYS, DIA, MEAN4.SpO2 | |
| Measurement and alarm range: 0 ~ 100% | |
| Resolution: 1% | |
| Measurement accuracy: 70%~100%: ±2%; | |
| 0%~69%: unspecified | |
| PR | Measurement and alarm range: 30 ~ 250bpm |
| Measurement accuracy: ±2bpm or ±2%, whichever is greater | |
| TEMP | Channel: dual-channel |
| Measurement and alarm range: 0 ~ 50℃ | |
| Resolution: 0.1 ℃ | |
| Label:ART, PA, CVP, RAP, LAP, ICP, P1, P2 | |
| Measuring and alarm range | |
| ART : 0 ~ 300mmHg | |
| PA: -6 ~ 120mmHg | |
| CVP/RAP/LAP/ICP : -10 ~ 40mmHg | |
| P1/P2: -10 ~ 300mmHg | |
| Press Sensor Sensitivity: 5uV/V/mmHg | |
| Impedance: 300-3000Ω | |
| Resolution: 1mmHg | |
| Accuracy: +-2% or +- 1mmHg, which great | |
| Actualization interval: about 1 Sec. 7.EtCO2 | |
| Method: Side-stream or Mainstream | |
| Measuring Range: 0~150mmHg | |
| Resolution: | |
| 0~69mmHg, 0mmHg | |
| 70~150mmHg, 0.2mmHg | |
| Accuracy: | |
| 0~40 mm Hg ±2mm Hg | |
| 41~70 mm Hg ±5% | |
| 71~100 mm Hg ±8% | |
| 101~150 mm Hg ±10% | |
| Aw-RR Range: 2~150 rpm | |
| Aw-RR Accuracy: ±1BPM | |
| Apnoea Alarm: Yes | |
| RESPARATION | Respiratory monitoring principle |
| Respiration is measured by the thoracic impedance. When the patient is breathing, the volume of air changes in the lungs, resulting in impedance changes between the electrodes. Respiration rate (RR) is calculated from these impedance changes, and a respiration waveform appears on the patient monitor screen. | |
| Method Impedance between R-F(RA-LL) | |
| Differential Input Impedance: >2.5MΩ | |
| Measuring Impedance Range:0.3~5.0Ω | |
| Base line Impedance Range:0 – 2.5KΩ | |
| Bandwidth: 0.3 ~ 2.5 Hz |
Product detail pictures:





Related Product Guide:
Our corporation puts emphasis about the administration, the introduction of talented staff, plus the construction of team building, attempting hard to improve the quality and liability consciousness of team members. Our organization successfully attained IS9001 Certification and European CE Certification of China Multifunction Semi-Modular Patient Monitor – H8 Multi Parameter Patient Monitor – Hwatime, The product will supply to all over the world, such as: Hanover , Stuttgart , Bangalore , Our next goal is to exceed the expectations of every client by offering outstanding customer service, increased flexibility and greater value. All in all, without our customers we do not exist; without happy and fully satisfied customers, we fail. We are looking for the wholesale, Drop ship. Please contact us if you are interesting our products. Hope to do business with you all. High quality and fast shipment!