Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of 12.1 Inch Portable Fetal Monitor , Ecg Spo2 Nibp Patient Monitor , Patient Monitoring Equipment , If possible, be sure to send your needs with a detailed list including the style/item and quantity you require. We will then deliver our greatest price ranges to you.
Best High Quality 6 Parameter Patient Monitor Factories – H8 Multi Parameter Patient Monitor – Hwatime Detail:

Quick Details

H8 Multi Parameter Patient Monitor (1)

ECG Lead mode: 3-lead or 5-lead

ECG Waveform: 4-lead, dual-channel 3-lead, single-channel

NIBP Mode: Manual, Auto, STAT

NIBP Measurement and alarm range: 0 ~ 100%

NIBP Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified

PR Measurement and alarm range: 30 ~ 250bpm

PR Measurement accuracy: ±2bpm or ±2%, whichever is greater

Application: Bedside/ICU/OR, Hospital/Clinic

Supply Ability: 100 Unit/Per Day

Packaging & Delivery:

Packaging Details

One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.

Product packaging size (length, width, height): 410MM*280MM*360MM

GW: 5.5KG

Delivery Port: Shenzhen, Guangdong

Lead Time:

Quantity(Units)

1 - 50

51 - 100

>100

Est. Time(days)

15

20

To be negotiated

Usage

Portable Patient Monitor can be used to monitor multiple physiological parameters including ECG(3-lead or 5-lead), Respiration(RESP), Temperature(TEMP), Pulse Oxygen Saturation(SPO2), Pulse Rate(PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure(IBP) and carbon dioxide(CO2). All the parameters can be applied for adult, pediatric and neonate patients. The monitoring information can be displaying, reviewing, storing and recording.

Product Description

Product name H8 Multi Parameter Patient Monitor
ECG Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s 2 RESPARATION Method Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5KΩ
Bandwidth: 0.3 ~ 2.5 Hz
NIBP Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN4.SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR Measurement and alarm range: 30 ~ 250bpm
Measurement accuracy: ±2bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50℃
Resolution: 0.1 ℃
Label:ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART : 0 ~ 300mmHg
PA: -6 ~ 120mmHg
CVP/RAP/LAP/ICP : -10 ~ 40mmHg
P1/P2: -10 ~ 300mmHg
Press Sensor Sensitivity: 5uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1mmHg
Accuracy: +-2% or +- 1mmHg, which great
Actualization interval: about 1 Sec. 7.EtCO2
Method: Side-stream or Mainstream
Measuring Range: 0~150mmHg
Resolution:
0~69mmHg, 0mmHg
70~150mmHg, 0.2mmHg
Accuracy:
0~40 mm Hg ±2mm Hg
41~70 mm Hg ±5%
71~100 mm Hg ±8%
101~150 mm Hg ±10%
Aw-RR Range: 2~150 rpm
Aw-RR Accuracy: ±1BPM
Apnoea Alarm: Yes
RESPARATION Respiratory monitoring principle
Respiration is measured by the thoracic impedance. When the patient is breathing, the volume of air changes in the lungs, resulting in impedance changes between the electrodes. Respiration rate (RR) is calculated from these impedance changes, and a respiration waveform appears on the patient monitor screen.
Method Impedance between R-F(RA-LL)
Differential Input Impedance:  >2.5MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5KΩ
Bandwidth: 0.3 ~ 2.5 Hz

Product detail pictures:

Best High Quality 6 Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

Best High Quality 6 Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

Best High Quality 6 Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

Best High Quality 6 Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures

Best High Quality 6 Parameter Patient Monitor Factories – 
 H8 Multi Parameter Patient Monitor – Hwatime detail pictures


Related Product Guide:

Our merchandise are broadly identified and trusted by end users and can satisfy continually developing economic and social requires for Best High Quality 6 Parameter Patient Monitor Factories – H8 Multi Parameter Patient Monitor – Hwatime, The product will supply to all over the world, such as: Cyprus , Estonia , Lithuania , As the world economic integration bringing challenges and opportunities to the xxx industry, our company , by carrying on our teamwork, quality first, innovation and mutual benefit, are confident enough to supply our clients sincerely with qualified merchandise, competitive price and great service, and to build a brighter future under the spirit of higher, faster, stronger with our friends together by carrying on our discipline.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 StarsBy Anna from Netherlands - 2017.11.01 17:04
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 StarsBy Michelle from Barbados - 2018.06.05 13:10

    Related Products