Best High Quality 2 Para Patient Monitor Pricelist – iHT9 Modular Patient Monitor – Hwatime
Best High Quality 2 Para Patient Monitor Pricelist – iHT9 Modular Patient Monitor – Hwatime Detail:
Quick Details

Quality Certification: CE&ISO
Instrument classification: Class II
Display: Colorful and Clear
Standard Parameter: ECG, RESP, NIBP, SpO2, PR, TEMP
Optional Parameter: IBP, EtCO2 Modular, 12 leads ECG, Touch screen, Printer
OEM: Available
Application: NICU, PICU, OR
Supply Ability: 100 Unit/Per Day
Packaging & Delivery:
Packaging Details
One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.
Product packaging size (length, width, height): 520*390*535mm
GW: 8kg
Delivery Port: Shenzhen, Guangdong
Lead Time:
|
Quantity(Units) |
1 - 50 |
51 - 100 |
>100 |
|
Est. Time(days) |
15 |
20 |
To be negotiated |
Product Description
| Product name | iHT9 Modular Patient Monitor |
| Product Details |
Technical Specifications:
ECG Number of leads: 3 or 5 leads Lead View: User select-able; I, II, III, aVR, aVL, aVF, V(5 leads); I, II, or III (3 leads) Gain selection: x1/4, x1/2, x1, and x2 Frequency Response: Diagnostic: 0.05 to 130HZ Monitor: 0.5 to 40 HZ Surgery: 1-20HZ Electrosurgery rotection: Yes Defibrillator Protection: Yes Pacer Detection/Rejection: Yes
Pulse Oximeter Range: 0% to 100% Resolution: 1% Accuracy: 70% to 100% range: ±2% 0% to 69% range: undefined Method: Dual wavelength LED
NIBP(Non – invasive Blood Pressure) Technique: Oscillometric during inflation Range: Adult: 40 to 270mmHg Pediatric: 40 to 200mmHg Neonate: 40 to 135mmHg Measurement Cycle: <40 sec. typical Automatic Measurement Cycles(Select-able): 1,2,3,5,10,15,30 min; 1,2,4,6 hr STAT Mode: 5 minutes of continuous readings Max. Allowable Cuff Adult: 300mmHg Pediatric: 240mmHg Neonate: 150mmHg Resolution: 1mmHg Transducer Accuracy: ±3mmHg
Heart(Pulse) Rate Source: User select-able: Smart, ECG PLETH, NIBP Range: NIBP: 40 to 240bpm ECG: 15 to 300bpm (Adult) 15 to 350bpm (Neonate) SPO2: 20 to 300bpm Accuracy: ±1bpm or ±1%(ECG) whichever is greater ±3bpm (SPO2, NIBP)
Temperature Channels: 2 Range, Accuracy: 28℃ to 50℃ (71.6F to 122F): ±0.1 ℃ Display Resolution: ±0.1℃
Respiration Rate Rate: 7 to 120bpm(ECG) Resolution: 1 breath/min Accuracy: ±2 breath/min
Trends Trend: 1 hour: resolution 1s or 5s 72 hours: resolution 1 min, 5mins, 10mins Display: tabular, graphical
Interface & Display Keys: 9; membrane activated Rotary knob: Push and rotate; 24 steps/turn Screen: 17 inch active color TFT Resolution: Internal display: 1024 x 768 pixels Wave forms: 16, maximum Wave forms Type: ECG Leads, I, II, III, aVR, aVL, aVF, V, RESP, PLETH
Printer(optional) Type: Thermal printer Paper Speed: 25mm/sec
Power Requirements Voltage: 100-250V AC; 50/60HZ Power Consumption: 70W, typical Battery: Lithium Battery Battery Life: 4 hours |
Product detail pictures:

Related Product Guide:
Our enterprise insists all along the standard policy of "product high-quality is base of business survival; client satisfaction could be the staring point and ending of an business; persistent improvement is eternal pursuit of staff" as well as consistent purpose of "reputation first, client first" for Best High Quality 2 Para Patient Monitor Pricelist – iHT9 Modular Patient Monitor – Hwatime, The product will supply to all over the world, such as: Panama , Burundi , Bangalore , We welcome you to visit our company & factory and our showroom displays various products that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to provide you with the best services. If you need more information, please do not hesitate to contact us via E-mail, fax or telephone.